Jump to content

Log in or register to remove this advert

treequip

Veteran Member
  • Posts

    10,076
  • Joined

  • Last visited

Everything posted by treequip

  1. There are only 2 valid management schemes for leylandii. 1 Top them 2 Fell them
  2. It weighs more
  3. You said The people interested in fuel (HMCE) have no jurisdiction over the other issues similarly those with jurisdiction over the other areas have no authority where fuels are concerned.
  4. hard black anodized aluminium Low friction rings
  5. Cant make my mind up, it feels a bit like some sort of ceramic but a bit like plastic in weight, lovely smooth things and light as can be.
  6. No the ring is the ring and its not metal. I spliced mine into whoopies because, well I thought they would be most useful like that. Why not use a biner, well the rings are low friction and have a much better bend radius.
  7. Make your own up The rings can be bought here (x rings is a rebranding of antal) Antal Low Friction Rings - From £8.25 - Force 4 Chandlery you can buy hollow braid from treeworker and if you can breathe you will be able to splice a whoopee sling together. Here are some I made [/img]
  8. Don't sweat it, it will all be fire wood in a year or so
  9. The issues are entirely unrelated
  10. Pahhh Back in the day 076. All the weight and more with a lot less power. Make a man of you
  11. Well done for that, you are the victim of my assumption. Most people prefer single handed operation then single handed life there after.
  12. A flow divider splits the flow into 2 pressure feeds, it can be used to control the speed of an action by reducing its flow and sending the un needed flow back to tank It can also be used to split the flow between 2 actions. The flow can be divided from 99/1 through 1/99
  13. In the current market Sub 750 is important The firewood market is buoyant so the need for big chippers is far less than it once was Which manufacturer are you?
  14. 100% More chance of catching your fingers where they shouldn't be. Remember, you have taken the machine outside any CE marking it might have had so don't let employees use it (on the assumption that you won't sue yourself)
  15. And of course you can back that claim up with official facts and figures cant you? The insurers are the ones who take a kicking on ringers, go to a salvage sale and try to buy a cat B write off.
  16. Save your money, I can tell you exactly what will happen Of you pipe them parallel neither will work, when you ask either to do anything the pressure will escape through the open centre of the other valve. If you synronise the operation of the valves both will work until one encounters a harder bit of timber it will stop working and only the other valve will work If you pipe them series (one after the other) the first valve (nearest the pump) will work fine but the other valve wont work at all while the first is in operation, if you fit a high pressure carry over (HPCO) to the first valve the second will work but only when the first isn't working, if you don't fit the HPCO, when you operate the second valve (with the first not operating) all sorts of weird and wonderful **** will happen with both valves. If you pipe to a flow divider and pipe the valves parallel from that all will be well
  17. So you have a live feed wire and a wire to the lamp, what else is there in the way of terminals and wires?
  18. illuminated switches usually have 3 terminals. live supply terminal switched feed (to the lamp) Earth to govern the function of the switch illumination You have the wires on the wrong terminals, swap them about
  19. Yes they are sure to be queuing up for that, and a conviction for fraud, significant fine and or a spell in pokey when caught I am pretty sure the powers that be have thought of that and primed the ANPR system to look out for the same truck passing a camera within minutes hundreds of miles apart
  20. The disk is going but you will still be able to pay the tax at the post office?????
  21. The point is that folks are moaning about the new system but that part hasn't changed.
  22. You take the V5 to the post office and tax it exactly the same as you do now
  23. :laugh1: But true
  24. If you run them on the existing valves with a single supply you will only be able to operate one at a time unless you fit a flow divider, even then you will only get 10l/min per unit, is that enough?

About

Arbtalk.co.uk is a hub for the arboriculture industry in the UK.  
If you're just starting out and you need business, equipment, tech or training support you're in the right place.  If you've done it, made it, got a van load of oily t-shirts and have decided to give something back by sharing your knowledge or wisdom,  then you're welcome too.
If you would like to contribute to making this industry more effective and safe then welcome.